YDP-J4 high temperature series parallel type constant power electric heat tracing


Yatailong constant power series: The Y DP-J4 high temperature series constant power electric heat belt developed and produced by the company is widely used in heat tracing, temperature maintenance, heat preservation and anticoagulation in many high-temperature occasions such as process pipelines, storage tanks, pumps and valves in the industrial field. The electric heat trace is suitable for general, hazardous and corrosive areas (different temperatures can be completed by our professional design).

Key words:

YDP-J4 high temperature series parallel type constant power electric heat tracing

Classification:

Parallel type constant power electric heating tape

Free consultation-Free design-Free delivery-Free guidance

  • Description
    • Commodity name: YDP-J4 high temperature series parallel type constant power electric heat tracing

    Yatailong constant power series: The Y DP-J4 high temperature series constant power electric heat belt developed and produced by the company is widely used in heat tracing, temperature maintenance, heat preservation and anticoagulation in many high-temperature occasions such as process pipelines, storage tanks, pumps and valves in the industrial field. The electric heat trace is suitable for general, hazardous and corrosive areas (different temperatures can be completed by our professional design).

    ► Product structure

    1. Strengthen the protective layer     2 Metal shield   3 Strengthened protective layer   4 Outer insulation 5  High-temperature fiberglass
    6. Fluoroplastic wrapping     7 Heating wire       8. Strengthen the protective layer 9Fluoroplastic wrapping  10High-temperature fiberglass
    11. Wire insulation (fluoroplastic)   12Silver-plated busbar

    ► The significance of the product model

    Product type:

    Parallel constant power electric heat tracing
    Nominal power (at 10°C).:40W/m、50W/m、60W/m

    Insulation grade:

    J4:PFA,260℃fluorine material

    Operating voltage:

    2:Single-phase 220V;3:Three-phase 380V

    Protection type:

    K (Shielded Type) KF (Shielded Reinforced Type)

    Commonly used models:

    YDP-J4-2K       YDP-J4-2KF

    YDP-J4-3K       YDP-J4-3KF

    Special specifications:It can be customized according to the special requirements of customers!

    ► Technical parameters

    Standard Colors:black, red;
    Temperature Range:

    The maximum maintenance temperature is 180°C~205°C (continuous power-on); 

    Maximum exposure temperature 260°C (intermittent power supply); 

    Construction Temperature:min. -40°C;
    Insulation Resistance:The minimum insulation resistance (between conductor and shield) is 500MΩ;
    Copper core wire:19*0.37、19*0.42
    Length of use:Single-phase power supply: 100-200m, dual-phase power supply: 200-400m (within the specified use length range, can be arbitrarily cut and cannot be crossed);
    Reinforced outer sheath:fluoroplastics;
    Metal Shielding:tinned copper wire/metal alloy;
    Outer insulation:high-temperature PTFE insulation;
    Wire shielding:High temperature resistant and fireproof fiberglass;
    Inner insulation:fluoroplastic wrapping;
    Heating wire material:nickel-chromium heating wire;
    Strengthened Protective Layer:fluoroplastics;
    Inner insulation:fluoroplastic wrapping;
    Wire shielding:High temperature resistant and fireproof fiberglass;
    Wire insulation:FEP fluoroplastics, PFA plastics;
    Wire Material:(environmentally friendly oxygen-free) silver-plated copper wire;
    Ingress Protection:IP67;

     

    ModelRated voltage(V)Rated power (W/m)    One-way maximum usage Length (m).The maximum maintenance temperature of the fluid is °CMaximum exposure temperature °C
    YDP40-J4-2KF22040130205260
    YDP50-J4-2KF22050110190260
    YDP60-J4-2KF22060100180260
    YDP40-J4-3KF38040200200260
    YDP50-J4-3KF38050180180260
    YDP60-J4-3KF38060150170260

     

    Maximum maintenance temperature of fluid: refers to the maximum process temperature that the medium in the pipeline needs to maintain, and generally should not exceed the value specified in this table.

    Maximum Exposure Temperature: Refers to the maximum withstand temperature of the process under conditions of intermittent power supply.

    When a single point of power is output using a bidirectional power junction box, the length of use can be doubled.

    ► Product features

    1.The parallel constant power electric belt is connected in parallel by multiple heating joints on the entire length, and the length can be cut according to actual needs;

    2.It must be used in conjunction with a thermostat to accurately set the medium maintenance temperature and high temperature overheating temperature to achieve automatic and safe control;

    3.Its calorific value per unit length is constant and stable, and the longer the electric heat trace used, the greater the total power output;

    4.It is flexible and can be close to the surface of the pipeline, and the outer metal shielding mesh can play the role of explosion-proof, anti-interference, heat transfer and heat dissipation, and improve the overall strength, safety and low heat loss of the electric heat tracing;

    5.The reinforced electric heating belt has the characteristics of high mechanical strength and strong anti-corrosion ability; 

    6.It has the characteristics of long service length, good heating uniformity, and three-phase can balance the load of the power grid; 

    7.High heating temperature and high temperature resistance level, suitable for high temperature maintenance and use in high temperature environment;

    8.Multi-layer high-temperature structure, silver-plated wire, safe, reliable and high-temperature resistance;

    9.No attenuation of power, high heat conversion rate, low operating cost; Long service life and low replacement cost; 

    10.It can not be overlapped, and it is easy to burn by overheating;

    ► Installation diagram

    ► Application scenarios

    ► Application cases

     

    Chemical pipeline valve insulation and heating project

    The community has increased the pump insulation and heating project

     

    Urumqi Petroleum Tank Insulation and Heating Project

    Liaoning Petroleum Long-distance Pipeline Heat Tracing Project

     

    Liaoning Petroleum Long-distance Pipeline Heat Tracing Project

    Inner Mongolia Chemical Process Pipeline Heating and Temperature Maintenance Project

    Key words:
    • YDP-J4 high temperature series parallel type constant power electric heat tracing

Previous Page

YDP-2a/J3 medium temperature double line 380V series parallel constant power super long electric heating tape

Product Consulting

Related Products