Products
-
Self-limiting electric heating tape
-
Industrial electric blanket/removable flexible protective cover
-
Industrial frequency conversion electromagnetic heating system
-
Specialized accessories for electric trace heating systems
-
Electric insulation and installation of integrated materials
YDP-2a/J3 medium temperature double line 380V series parallel constant power super long electric heating tape
Key words:
Classification:
Parallel type constant power electric heating tape
Free consultation-Free design-Free delivery-Free guidance
- Description
-
- Commodity name: YDP-2a/J3 medium temperature double line 380V series parallel constant power super long electric heating tape
Yatai Long constant power series: The company develops and produces the YDP-2a/J3 medium temperature series constant power electric accompanying heat tape, widely used in the industrial field of process pipeline, storage tank, pump valve and so on many occasions of accompanying heat, antifreeze, dimensional warmth, heat preservation, anticoagulation. The electric accompanies the tropical belt to apply to the ordinary area, the dangerous area and the corrosive area (the different temperatures can be completed through the company's professional design).
► Product Structure

1. Tinned copper core wire 2. Power supply insulation layer (fluorine material) 3. Inner sheath insulation layer (fluorine material) 4. Nickel-chromium alloy heating wire
5. Outer sheath insulation layer (fluorine material) 6. Metal shielding layer 7. Reinforced protective layer (fluorine material)
► Product model meaning

product type:
Parallel constant power electric heating cable Nominal power (@10℃): 10~60W/m Insulation level:
J3: F46, 205℃ fluorine material
Operating Voltage:
2a: Three-phase 380V Protection type:
K (shielded type) KF (shielded reinforced type) Common models:
YDP-2a/J3-3K、YDP-2a/J3-3KF Special specifications: Can be customized according to customer's special requirements! ► Technical Parameters
Standard colors:
Brown, red;
temperature range:
The maximum maintenance temperature is 60℃~130℃ (continuous power on);
Maximum exposure temperature 205°C (intermittent power supply);
Application temperature:
Minimum -40℃;
Insulation resistance:
The minimum insulation resistance (between conductor and shield) is 500MΩ;
Copper core conductor:
19×0.32mm²、19×0.37mm²、19×0.42mm²;
Use length:
One-way power supply: 150-400m, two-way power supply: 300-800m (within the specified length range, it can be cut arbitrarily and cannot be crossed or overlapped); Conductive busbar material:
(Environmentally friendly oxygen-free) tinned copper wire/nickel-plated copper wire; Wire Insulation Material: Fluoroplastic; Inner sheath insulation layer:
Fluoroplastic; Alloy heating wire: Nickel-chromium high temperature alloy; Outer sheath layer: Fluoroplastic; Metal shielding layer:
Metal alloy wire/tinned copper wire;
Strengthen the protective layer:
Fluorine materials;
Protection level: IP67; model Rated voltage (V) Rated power (W/m) Maximum length for one-way use (m) Maximum fluid temperature (°C) Maximum tolerance temperature (℃) YDP10-2a/J3-2KF 380 10 400 150 205 YDP20-2a/J3-2KF 380 20 350 130 205 YDP30-2a/J3-2KF 380 30 300 120 205 YDP40-2a/J3-2KF 380 40 225 100 205 YDP50-2a/J3-2KF 380 50 180 80 205 YDP60-2a/J3-2KF 380 60 150 60 205 Maximum fluid maintenance temperature: refers to the maximum process temperature that the medium in the pipeline needs to maintain, which generally should not exceed the value specified in this table.
Maximum exposure temperature: refers to the maximum temperature that the process can withstand under conditions of intermittent power supply.
Maximum one-way use length: refers to the use length of the copper core wire with a conductor cross-sectional area of 19*0.42mm².
► Product Benefits
1. Parallel constant power electric heating belt consists of multiple heating sections connected in parallel along the entire length, and can be cut to length according to actual needs;
2. When heating, it must be used in conjunction with a thermostat to accurately set the medium maintenance temperature and achieve automatic control.
3. The heat generated per unit length is constant. The longer the heating tape used, the greater the total output power.
4. The electric heating belt is soft and can be attached to the surface of the pipe. The outer metal shielding net can play the role of anti-interference, heat transfer and heat dissipation, improve the overall strength of the electric heating belt, and can also be used as a safety grounding wire.
5. The reinforced electric heating belt also has the characteristics of high mechanical strength and strong anti-corrosion ability.
6. The three-phase parallel constant power electric heating belt has the characteristics of long maximum use length, good heating uniformity, and can balance the grid load.

► Installation diagram

► Applications

► Application Cases
Key words:- YDP-2a/J3 medium temperature double line 380V series parallel constant power super long electric heating tape