- Commodity name: YDP-J3 medium temperature series parallel type constant power electric heat tracing
Yatailong constant power series: the YDP-J3 medium temperature series constant power electric belt developed and produced by the company is widely used in heat tracing, anti-freezing, temperature maintenance, heat preservation and anticoagulation in many occasions such as process pipelines, storage tanks, pumps and valves in the industrial field. The electric heat trace is suitable for general, hazardous and corrosive areas (different temperatures can be completed by our professional design).
► Product structure


1. Conductive busbar 2. Wire insulation (fluoroplastic) 3. Inner sheath insulation (fluoroplastic). 4. Nichrome heating wire
5. Outer sheath (fluoroplastic) 6. Metal shield (metal alloy/tinned copper). 7. Strengthen the protective layer (fluoroplastic).
► The significance of the product model

Product type:
Parallel constant power electric heat tracing Nominal power (at 10°C).: 10W/m、20W/m、30W/m、40W/m、50W/m、60W/m Insulation grade:
J3: F46, 205°C Fluoroplastics Operating voltage:
2:Single-phase 220V;3:Three-phase 380V Protection type:
K (Shielded Type) KF (Shielded Reinforced Type) Commonly used models:
YDP-J3-2K YDP-J3-2KF
YDP-J3-3K YDP-J3-3KF
Special specifications: It can be customized according to the special requirements of customers! ► Technical parameters
Standard Colors:
brown, red; Temperature Range:
The maximum maintenance temperature is 60°C~150°C (continuous power-on);
Maximum exposure temperature 205°C (intermittent power supply);
Construction Temperature:
min. -40°C; Insulation Resistance:
The minimum insulation resistance (between conductor and shield) is 500MΩ; Length of use:
19×0.32、19×0.37、19×0.42;
One-way power supply:
130-330m, two-way power supply: 260-660m (within the specified use length, can be arbitrarily cut, can not be crossed); Conductive bus material:
(environmentally friendly oxygen-free) tinned copper wire/nickel-plated copper wire; Wire insulation: fluoroplastics; Inner sheath insulation:
fluoroplastics; Alloy heating wire: Nichrome heating wire; Outer sheath: fluoroplastics; Metal Shielding:
metal alloys/tinned copper; Strengthened Protective Layer:
fluoroplastics;
Ingress Protection: IP67; Model Rated voltage(V) Rated power(W/m) Maximum length (m) for one-way use The maximum maintenance temperature of the fluid is °C Maximum exposure temperature °C YDP10-J3-2KF 220 10 210 150 205 YDP20-J3-2KF 220 20 180 120 205 YDP30-J3-2KF 220 30 150 90 205 YDP40-J3-2KF 220 40 130 65 205 YDP30-J3-3KF 380 30 330 120 205 YDP40-J3-3KF 380 40 280 100 205 YDP50-J3-3KF 380 50 275 80 205 YDP60-J3-3KF 380 60 250 60 205 Maximum maintenance temperature of fluid: refers to the maximum process temperature that the medium in the pipeline needs to maintain, and generally should not exceed the value specified in this table.
Maximum Exposure Temperature: Refers to the maximum withstand temperature of the process under conditions of intermittent power supply.
When a single point of power is output using a bidirectional power junction box, the length of use can be doubled.
► Product features
1.The parallel constant power electric belt is connected in parallel by multiple heating joints on the entire length, and the length can be cut according to actual needs;
2.It must be used in conjunction with a thermostat to accurately set the medium maintenance temperature and high temperature overheating temperature for automatic and safe control.
3.Its calorific value per unit length is constant and stable, and the longer the heat belt used, the greater the total power output.
4.It has flexibility, can be close to the surface of the pipe, and the outer metal shielding mesh can play the role of explosion-proof, anti-interference, heat transfer and heat dissipation, and improve the overall strength, safety and low heat loss of the electric heat tracing.
5.The reinforced electric belt also has the characteristics of high mechanical strength and strong anti-corrosion ability.
6.It has the characteristics of long service length, good heating uniformity, and three-phase can balance the load of the power grid.
7.Multi-layer insulated corrosion-resistant and heat-resistant structure, tinned wire, safe and reliable.
8.No attenuation of power, high heat conversion rate, low operating cost; Long service life and low replacement cost;
9.It can not be overlapped, and it is easy to burn by overheating;

► Installation diagram

► Application scenarios

► Application cases

Chemical pipeline valve insulation and heating project

The community has increased the pump insulation and heating project

Urumqi Petroleum Tank Insulation and Heating Project

Liaoning Petroleum Long-distance Pipeline Heat Tracing Project

Liaoning Petroleum Long-distance Pipeline Heat Tracing Project

Inner Mongolia Chemical Process Pipeline Heating and Temperature Maintenance Project