Picture Name

400-624-8818

--Service hotline——

Products

+
  • 电源接线盒.png

Power supply junction box


The power supply junction box is used for the connection of the power supply line and the accompanying electric heat tape. Generally fixed in the pipeline, and accompanied by the electric heating belt supporting the factory in one area, two areas of explosive gas mixtures T4 group field use. Explosion-proof power junction box can be both one-way output, and two-way output.

Key words:

Power supply junction box

Classification:

Power supply junction box

Specialized accessories for skin effect heat tracing systems

Free consultation-Free design-Free delivery-Free guidance

  • Description
    • Commodity name: Power supply junction box

    The power supply junction box is used for the connection of the power supply line and the accompanying electric heat tape. Generally fixed in the pipeline, and accompanied by the electric heating belt supporting the factory in one area, two areas of explosive gas mixtures T4 group field use. Explosion-proof power junction box can be both one-way output, and two-way output.

    The power junction box is used to connect the power line and the heating cable. It is usually fixed on the pipeline and is suitable for factory use after matching with the heating cable. The power junction box can output in one direction or two directions.

     

    FBDH-I

    FBDH-II

    FBDH-III

    ► Main technical parameters

    model

    FBDH-I

    FBDH-II

    FBDH-III

    Material

    ABS

    DMC

    SMC

    Rated voltage

    220/380 VAC

    220/380 VAC

    220/380 VAC

    Rated current

    40 A

    40 A

    40 A

    proper temperature

    -40~+85 ℃

    -40~+260 ℃

    -40~+150℃

    Cable thread

    G1/2

    G1/2

    -

    Protection level

    IP55

    IP55

    IP65

    ► Product Details

    ► Product structure and installation diagram

    ► Notes

    1. If the junction box casing is found to be deformed, cracked or damaged, stop using it and replace it with a new one.

    2. During installation, prevent short circuit between the outer braided copper wire and the heating wire and core wire, and ensure that the electrical clearance is not less than 8mm and the creepage distance is not less than 10mm.

    3. When the redundant holes of the junction box are not in use, they should be blocked with a blocking plate with a thickness of not less than 2mm.

    4. Connect the power supply cable to the power junction box. When the current is less than 15A, use 3×2.5mm2 rubber sheathed cable; when the current is greater than 15A, use 3×4mm2 rubber sheathed cable.

    5. The power junction box is equipped with a grounding terminal for grounding the heating tape.

    6. When the power grounding box is used on the buried pipe, seal it with 702 glue at the cable inlet after installation, and pay attention to waterproof sealing.

    Key words: