- Commodity name: Antares Medium Temperature Self-limiting Tropical Tapes
Antal middle temperature series: The company develops and produces the ZBR series intelligent temperature control electric accompanying heat tape, widely used in the industrial field of water supply and drainage pipeline, process pipeline, storage tanks and so on many occasions of accompanying heat, dimensional warmth, heat preservation, anticoagulation. The electric accompanying heat tape is suitable for common area, dangerous area and corrosion area. (105 ℃ below the maintenance temperature requirements, can be completed through the company's professional design
► Product Structure
ZBR-2KF

ZBR-2KF/F4

1.Tinned copper core wire
2.Conductive plastic (heat PTC)
3.Inner insulation layer (modifiedpolyolefin/low smoke halogenfree/fluorinated)
4.Metal shielding layer (metal alloywire/tinned copper wire)
5. Sheath (modifiedpolyolefin/low smoke and halogen free/fluorinated type))
► Model Number Meaning

Temperature Class
T4 (135°C) Product type
Self-limiting heating tape Nominal power (@10℃)
26W/m、33W/m、49W/m、66W/m
Working Voltage
110V-380V ( DC/AC)
Protection class
J (Basic type) K (Shielded type)
KF (Shielded reinforced type) F4 (Fluorinated type)
Commonly used models
ZTV-2J ZTV40-2K
ztv-2kf ztv-2kf/f4 ztv-2kf/2f4
Special specification
Can be processed and customized according to customers' special requirements! ► Technical parameters
Standard colors:
Dark red, brown; Temperature range:
Maximum sustaining temperature 105°C ± 5°C (continuously powered);
Maximum sustaining temperature 135°C ± 5°C (intermittently energized);
Construction temperature:
Minimum -40°C;
Thermal stability:
After 1500 cycles between 10℃ and 99℃, the heat generation of the cable is maintained above 95% , and the heat conversion rate is 95%;
Bending radius:
23.8mm at 20°C room temperature, 38.0mm at -30°C low temperature;
Insulation resistance:
Electric accompanied by tropical length of 100m, the ambient temperature of 75 ℃, with 2500VDC shaking table shaking test for one minute, insulation resistance (wire and shielding between) the minimum value of 120MΩ;
Starting current:
When the electric heating tape is energized, the maximum value of instantaneous starting current ≤ 0.5A/m;
Copper core conductor:
7 x 0.5, 19 x 0.28, 19 x 0.32; Use length:
Single-phase power supply: 100m, two-phase power supply: 200m (within the specified use length, can be arbitrarily cut, arbitrarily connected, cross overlap);
Conductor material:
Tinned copper wire; PTC conductive plastic: Fluorine-containing type, common type; Inner insulation: Modified polyolefin/low smoke halogen free/fluorinated type; Metal Shield:
Tinned copper wire or metal alloy wire braid;
Outer jacket layer: Modified polyolefin/low smoke halogen free/fluorinated; Protection rating:
IP65; Curve diagram: 
► Product advantages
1. Wide range of applications: petroleum, chemical industry, iron and steel, electric power and other commercial and industrial fields of pipelines, tanks of anti-freezing, heat preservation, anticoagulation, maintenance of temperature, the electric accompanied by tropical strip is suitable for ordinary, hazardous and corrosive areas;
2. Temperature control accurately, will not overheat or heat bad, safe and reliable;
3. Accompanied by uniform heat, high thermal efficiency;
4. Saving electricity, no environmental pollution, energy saving and environmental protection;
5. When intermittent operation, warming start fast;
6. Low accompanying heat power, low annual attenuation rate, long service life;
7. Easy installation and maintenance, low running cost;
8. Easy automation management;
9. Small starting current, low cost of distribution in the early stage, long service life, low maintenance cost in the later stage, low power consumption in long-term operation, high heat conversion rate;