Products
-
Self-limiting electric heating tape
-
Industrial electric blanket/removable flexible protective cover
-
Industrial frequency conversion electromagnetic heating system
-
Specialized accessories for electric trace heating systems
-
Electric insulation and installation of integrated materials
YDP-G3-2KF Silicone gel series parallel connection type constant power electric heating tape
Key words:
Classification:
Parallel constant power heating lines
Free consultation-Free design-Free delivery-Free guidance
- Description
-
- Commodity name: YDP-G3-2KF Silicone gel series parallel connection type constant power electric heating tape
Yatai Long constant power series: The company develops and produces the YDP-G3-2KF silica gel series parallel type constant power electric accompanying heat tape, widely used in the industrial field of the building, cold storage and warehouse ground, ramp, eaves trough and roof and so on many occasions of the heating, antifreeze, dimensional warmth, heat preservation, anticoagulation, defrosting.The electric accompanies the tropical belt to apply to the ordinary area, the dangerous area and the corrosive area (the different temperature can be completed through the company's professional design).
► Product Structure
YDP-G3-2KF

1. conductive busbar
2. conductor insulation (insulating silicone rubber)
3. nickel-chromium alloy heating wire
4. Inner sheath layer (insulating silicone rubber)
5. metal shield (tinned copper)
6. Sheath (silicone rubber/fluoroplastic)
► Model Number Meaning

Product Type
Parallel constant power electric heating tape Nominal power(@10℃)
25~60W/m
Insulation grade
G3: Silicone Rubber
Working Voltage
2:Single-phase 220V
Protection grade
KF (shielded reinforced)
Common Model
YDP-G3-2KF Special specifications Can be processed and customized according to customers' special requirements!
► Technical parameters
Standard colors:
Brown, Red;
Temperature range:
Maximum maintained temperature 60°C to 130°C (continuously powered);
Maximum withstand temperature 205°C (intermittent power supply);
Construction temperature:
Minimum -40°C;
Insulation resistance:
Insulation resistance (between conductor and shield) is 500 MΩ minimum;
Copper core conductors:
19×0.32mm², 19×0.37mm², 19×0.42mm² Length of use:
Single-phase power supply: 100m, two-phase power supply: 200m (within the specified use length, can be arbitrarily cut, arbitrarily connected, cross overlap);
Wire material:
(environmentally friendly oxygen-free) tinned copper wire/nickel-plated copper wire; Wire insulation:
Insulating silicone rubber;
Alloy heating wire:
Nickel-chromium high-temperature alloy; Inner insulation:
Insulating silicone rubber; Metal shielding:
Tinned copper wire or metal alloy wire braid;
Outer sheath layer:
Silicone rubber/fluoroplastic;
Protection rating: IP67;
Model
Rated voltage (V) Rated power (W/m) Unidirectional maximum use length (m) Maximum sustaining temperature of fluid (℃) Maximum withstand temperature (℃) YDP25-G3-2KF
220 25 65 60 205 YDP40-G3-2KF
220 40 50 90 205 YDP50-G3-2KF
220 50 44 100 205 YDP60-G3-2KF
220 60 20 120 205 Fluid maximum sustaining temperature: is the maximum process temperature of the medium to be maintained in the pipeline, generally should not exceed the value specified in this table.
Maximum exposure temperature: is the maximum withstand temperature in and intermittent power supply conditions for the process tolerance temperature.
When a single point power supply is used with a bi-directional power junction box output, the length used can be doubled.
► Product Advantages
1、Parallel constant power electric heating tape consists of several heating sections connected in parallel over the whole length, which can cut the length according to the actual need;
2, the heat must be used in conjunction with the thermostat, which can accurately set the medium to maintain the temperature and realize automatic control.
3, the unit length of the heat generation is constant, the longer the use of electric heat tape, the greater the total power output.
4, electric heat tape because of its softness, can be close to the surface of the pipe, the outer metal shielding network can play a role in explosion-proof, anti-interference and heat transfer and heat dissipation, to improve the overall strength of the electric heat tape, but also can be used as a safety grounding line.
5, good temperature resistance.The overall use of silicone for insulation and thermal conductive materials (including power cord), the working environment temperature of -60 to ± 200C.
6, good thermal conductivity: through the heat can be generated, direct thermal conductivity, high thermal efficiency, short-term heating to achieve results.
7, reliable electrical performance: each electric hotline factory, after strict DC resistance, water immersion and insulation resistance and other tests to ensure quality.
8, sturdy structure, flexible and easy to bend; combined with the overall cold tail section, no bonding point; reasonable structure, easy to install.
9、Strong designability; heating length, lead length, rated voltage and power are determined by the user.

► Installation diagram

► Applications

► Application Cases
Chemical pipeline valve insulation accompanied by heat project
Increase pump thermal insulation and accompanying heat project 

Xinjiang Petroleum Tank Insulation Accompanying Heat Project
Urumqi Petroleum Tank Insulation and Heat Tracing Project 

Liaoning Petroleum Long-distance Pipeline Heat Tracing Project
Inner Mongolia Chemical Process Pipeline Tracer Heat Maintenance Project 
Key words:- YDP-G3-2KF Silicone gel series parallel connection type constant power electric heating tape
Previous Page
None
Next Page
Product Consulting
Related Products