Anti-freezing heat tracing system for fire-fighting pipelines
-
Power plant desulphurisation and denitrification accompanying heat insulation system
-
Power plant grey hopper heat tracing and temperature maintenance system
-
Oil and gas pipeline heat tracing and temperature maintenance system
-
Industrial inverter electromagnetic heating application system
-
Long distance heat tracing system for long distance pipelines
-
Chemical raw material pipeline heat tracing and temperature maintenance system
-
Offshore Drilling Platform Pipe Pump Tank Heat Tracing System
-
Industrial pipeline anti-freezing heat tracing and temperature maintenance system
Prescription
-
-
Self-limiting electric heating tape
-
Railroad turnout snow melting and ice melting system
-
Flexible Silicone Heating Products
-
Industrial electric blanket/removable flexible protective cover
-
Industrial frequency conversion electromagnetic heating system
-
Specialized accessories for electric trace heating systems
-
Electric insulation and installation of integrated materials
Product Center
-
-
-
Technical Support
-
Engineering Projects
-
-
天津亚泰龙热控科技有限公司是一家专注电加热产品及配套热控系统、设计、制造、销售、技术咨询、工程规划、系统设计与施工等服务为一体的公司。
天津亚泰龙热控科技有限公司是一家专注电加热产品及配套热控系统、设计、制造、销售、技术咨询、工程规划、系统设计与施工等服务为一体的公司。
天津亚泰龙热控科技有限公司是一家专注电加热产品及配套热控系统、设计、制造、销售、技术咨询、工程规划、系统设计与施工等服务为一体的公司。
天津亚泰龙热控科技有限公司是一家专注电加热产品及配套热控系统、设计、制造、销售、技术咨询、工程规划、系统设计与施工等服务为一体的公司。
400-624-8818
--Service hotline——
Technical Support
How to solve the problem of tripping circuit breaker in the electric heat trace circuit?
发布时间:
-
File size: 15.5KB
► Reason (1)
1. The circuit breaker is too small;
2. The power demand of the line exceeds the power supply of the circuit breaker;
3. The circuit breaker is activated at a lower than the design starting temperature;
► Corrective Methods
Recalculate the power required for the check line and then select the circuit breaker (the power supply cable should also be selected);
► Reason (2)
circuit breaker failure;
► Corrective Methods
Overhaul of circuit breakers;
► Reason (3)
1. There is a short circuit in the junction box or other accessories;
2. Mechanical damage to the electric heat tracing;
► Corrective Methods
1. Determine where the fault is, reinstall or replace, and test with a shake meter, and determine the short circuit method as follows:
2. Whether the installation of all wiring accessories is intact and whether the waterproof seal is damaged;
3. Whether the pipe fittings have been repaired and caused damage to the electric heat tracing;
4. Whether the insulation layer is damaged or crushed;
5. Isolate each section of the electric heat trace of the line and test the fault with a shake meter;
► Reason (4)
1. Mistakenly connect the two wires of the electric heat trace at the end end;
2. The insulation layer of the first and last section of the electric heat trace is thermally contracted, and the conductor is short-circuited with the pipeline or shield;
► Corrective Methods
1. Check whether all wiring accessories are installed and whether the waterproof seal is damaged;
2. Whether the pipe fittings have been repaired and caused damage to the electric heat;
3. Whether the insulation layer is damaged or crushed;
► Reason (5)
1. Excessive moisture accumulation in the junction box or accessories;
2. There are cracks in the heat trace or power supply cable and there is moisture;
► Corrective Methods
1. Dry the faulty place and reinstall it and then test it with a shake watch;
2. There will be a faulty section to replace;
national unified service hotline: 400-624-8818
Marketing Hotline: 86-022-87887111/87887222/87887333
Technical hotline: 86-022-23767222
Fax service: 86-022-26799118
Enterprise E-mail: ytl@yatalo.com.cn
Enterprise official website:www.yatalo.com
Marketing Exhibition Center: No. 111, Building 1, Beifangcheng District 2, Miyun Road, Nankai District, Tianjin (Yatailong Office Building)
Production R & D Address: Tianjin Binhai New Area Huayuan Industrial Park Haitai International Industrial Base
Micro-Blog
Website
Service Number
Subscription Number
-
-
-
Anti-freezing heat tracing system for fire-fighting pipelines
-
Power plant desulphurisation and denitrification accompanying heat insulation system
-
Power plant grey hopper heat tracing and temperature maintenance system
-
Oil and gas pipeline heat tracing and temperature maintenance system
-
Industrial inverter electromagnetic heating application system
-
Long distance heat tracing system for long distance pipelines
-
Chemical raw material pipeline heat tracing and temperature maintenance system
-
Offshore Drilling Platform Pipe Pump Tank Heat Tracing System
-
Industrial pipeline anti-freezing heat tracing and temperature maintenance system
-
-
-
Self-limiting electric heating tape
-
Flexible Silicone Heating Products
-
Industrial electric blanket/removable flexible protective cover
-
Industrial frequency conversion electromagnetic heating system
-
Specialized accessories for electric trace heating systems
-
Electric insulation and installation of integrated materials
-
-